COPY
UNITED STATES TESTING COMPANY, INC.
HOBOKEN, NJ
NUMBER
67323
REPORT
March 25, 1960
Subject:
Two (2) samples of adhesives, sampled and identified by Client, for tensile shear tests before and after oxygen aging.
Test Procedure:
Two panels of each type of adhesive were prepared and tested in accordance withe the procedure outlined in Military Specification MIL-A-5090B, amendment 1, dated 15 March, 1955. One panel of each type adhesive was tested at room temperature and one panel of each type adhesive was tested after 3 days oxygen aging.
Tensile Shear Strength, psi.
| Room Temperature |
|
Oxygen Aged |
| Specimen |
EC 800 |
4719 |
|
EC 800 |
4719 |
| 1 |
5.7 |
10.0 |
|
19.8 |
50.2 |
| 2 |
4.6 |
16.6 |
|
22.0 |
51.3 |
| 3 |
3.5 |
6.7 |
|
21.5 |
46.3 |
| 4 |
4.2 |
5.7 |
|
22.0 |
31.4 |
| 5 |
2.5 |
5.9 |
|
17.7 |
49.1 |
| Average |
4.1 |
9.0 |
|
20.6 |
45.7 |